Product Details
PHS Series
PHS-130
- Model:PHS-130
About this product
◆ Can dry rapidly, evenly at low temperature.
◆ The rate of broken rice would be low and the appearance rice will be beautiful, achieving high milling yield.
◆ Can use rice husk as biomass fuel to minimize drying costs.
◆ The rate of broken rice would be low and the appearance rice will be beautiful, achieving high milling yield.
◆ Can use rice husk as biomass fuel to minimize drying costs.
Product Introduction
PHS-130 Series
• The low-temp., even and speedy drying minimizes broken rice, raises milling rate and produces beautiful rice.
• The entire dryer is designed to be strong and sturdy, making it suitable for heavy-duty.
• With foolproof design, users can produce high-quality rice from the 1st, 100th to 1000th batch.
Small-package rice consistent in quality will be available to customers.
• Automatic moisture control prevents over-drying and weight loss.
• By using self-milled free rice husk, users no longer need to spend on diesel, natural gas or electricty as dryers' heat sources.
Multiple models with various fuel options availabl
Application


Specifications Unit mm
Dimensions

• The low-temp., even and speedy drying minimizes broken rice, raises milling rate and produces beautiful rice.
• The entire dryer is designed to be strong and sturdy, making it suitable for heavy-duty.
• With foolproof design, users can produce high-quality rice from the 1st, 100th to 1000th batch.
Small-package rice consistent in quality will be available to customers.
• Automatic moisture control prevents over-drying and weight loss.
• By using self-milled free rice husk, users no longer need to spend on diesel, natural gas or electricty as dryers' heat sources.
Multiple models with various fuel options availabl
Heat Source | PHS-130 Series |
Diesel | ● |
Gas | ● |
Biomass | ● |
Diesel & Husk Dual | ● |
Gas & Husk Dual | ● |
Steam | - |
Application



Specifications Unit mm
Item | PHS-130 | ||
Heat Source | Kerosene or Premium Diesel* | ||
Combustion Approx. liter/hr | 8.8~17.5 | ||
Type | Gun type | ||
Capacity Approx. kg | Paddy 1 liter=560g | 3,600~13,000 | |
Wheat 1 liter=680g | 4,370~15,780 | ||
Corn, Animal Feed 1 liter=690g | 4,440~16,000 | ||
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 4,308×2,755×9,698 | |
With CL-10 | Horizontal Type | 7,393×2,755×9,698 | |
Vertical Type | Please contact the sales department | ||
Net Weight Approx. kg | Without CL-10 | 2,840 | |
With CL-10 | Horizontal Type | 3,344 | |
Vertical Type | Please contact the sales department | ||
Power Consumption kW | Without CL-10 | 6.53 | |
With CL-10 | 10.33 | ||
Function Paddy | Loading Approx. mins | 40 | |
Discharging Approx. mins | 35 | ||
Drying Rate %/hr | 0.5~1.5 | ||
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz | ||
Safety Devices | Thermo-over relay, Air pressure switch, Full load buzzer, Timer, Control fuse, Rotary valve sensor, Burner flame sensor, Over-heat sensor |
*Use high-quality kerosene or premium diesel only
Item | PHS-130B | ||
Heat Source | SUNCUE Biomass Furnace BB-18, SUNCUE Rice Husk Furnace SB | ||
Capacity Approx. kg | Paddy 1 liter=560g | 3,600~13,000 | |
Wheat 1 liter=680g | 4,370~15,780 | ||
Corn, Animal Feed 1 liter=690g | 4,440~16,000 | ||
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 4,532×2,755×9,698 | |
With CL-10 | Horizontal Type | 7,617×2,755×9,698 | |
Vertical Type | Please contact the sales department | ||
Net Weight Approx. kg | Without CL-10 | 2,950 | |
With CL-10 | Horizontal Type | 3,454 | |
Vertical Type | Please contact the sales department | ||
Required Thermal Energy per unit | Paddy ? Wheat Approx. Kcal/hr | 35,000~135,000 Ambient Temp. +10~40°C | |
Corn ? Animal Feed Approx. Kcal/hr | 220,000 Ambient Temp. +65°C | ||
Power Consumption kW | Without CL-10 | 7.98 | |
With CL-10 | 11.78 | ||
Function Paddy | Loading Approx. mins | 40 | |
Discharging Approx. mins | 35 | ||
Drying Rate %/hr | 0.5~1.5 | ||
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz | ||
Safety Devices | Thermo-over relay, Air pressure switch, Full load buzzer, Timer, Control fuse, Rotary valve sensor |
Item | PHS-130G | |||
Heat Source | LPG | NG | ||
Max. Combustion Approx. | 16.6 kg/hr≒233kW | 18.2 m3/hr≒233kW | ||
Type | Gun type | |||
Capacity Approx. kg | Paddy 1 liter=560g | 3,600~13,000 | ||
Wheat 1 liter=680g | 4,370~15,780 | |||
Corn, Animal Feed 1 liter=690g | 4,440~16,000 | |||
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 4,308×2,755×9,698 | ||
With CL-10 | Horizontal Type | 7,393×2,755×9,698 | ||
Vertical Type | Please contact the sales department | |||
Net Weight Approx. kg | Without CL-10 | 2,840 | ||
With CL-10 | Horizontal Type | 3,344 | ||
Vertical Type | Please contact the sales department | |||
Power Consumption kW | Without CL-10 | 6.68 | ||
With CL-10 | 10.48 | |||
Function Paddy | Loading Approx. mins | 40 | ||
Discharging Approx. mins | 35 | |||
Drying Rate %/hr | 0.5~1.5 | |||
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz | |||
Safety Devices | Thermo-over relay, Air pressure switch, Full load buzzer, Timer, Control fuse, Rotary valve sensor, Burner flame sensor, Over-heat sensor |
Dimensions

Product Remark
◆Above numbers and drying rate are derived from reducing moisture in paddy from 26% to 15%, wheat/corn from 30% to 12.5% ─ for reference only. Actual results vary among different ambient temperature, relative humidity, grain varieties, hot air temperature, moisture content before and after drying.
◆Please apply low hot air temperature for drying paddy to prevent high breakage rate.
◆Gas pipe lines have to be built by certified local professionals. NEVER do it by yourself.
◆The required thermal energy is for reference only. Actual data will differ among grain variety, impurity rate, and drying condition.
◆Diesel/Rice Husk & Gas/Rice Husk Duel-type are made to order.
◆The specification and graph are for reference only. Actual specification of SUNCUE product shall be based on the Sales Confirmation which customers sign and delivered products.
◆The specifications of burner shown above are Japanese standard (Thermal energy: NG 11,000 Kcal/m3; LPG 12,000 Kcal/kg). Please consult with SUNCUE for burner with CE standard.
◆The density, composition and pressure of natural gas vary at different locations, thus thermal energy per m3 also varies. Ex: 8,900 Kcal/m3 in Taiwan, 11,000 Kcal/m3 in Japan, 8,400 Kcal/m3 in Sichuan province of China.
◆Different platform, rain hood, exhaust chamber, exhaust pipe, stand, balustrade and other accessories are required for each dryer and CL-10 model.
◆The user shall prepare dust collecting bags when using CL-10 without a central dust collecting system.
◆Please apply low hot air temperature for drying paddy to prevent high breakage rate.
◆Gas pipe lines have to be built by certified local professionals. NEVER do it by yourself.
◆The required thermal energy is for reference only. Actual data will differ among grain variety, impurity rate, and drying condition.
◆Diesel/Rice Husk & Gas/Rice Husk Duel-type are made to order.
◆The specification and graph are for reference only. Actual specification of SUNCUE product shall be based on the Sales Confirmation which customers sign and delivered products.
◆The specifications of burner shown above are Japanese standard (Thermal energy: NG 11,000 Kcal/m3; LPG 12,000 Kcal/kg). Please consult with SUNCUE for burner with CE standard.
◆The density, composition and pressure of natural gas vary at different locations, thus thermal energy per m3 also varies. Ex: 8,900 Kcal/m3 in Taiwan, 11,000 Kcal/m3 in Japan, 8,400 Kcal/m3 in Sichuan province of China.
◆Different platform, rain hood, exhaust chamber, exhaust pipe, stand, balustrade and other accessories are required for each dryer and CL-10 model.
◆The user shall prepare dust collecting bags when using CL-10 without a central dust collecting system.